Davis, AK., et al., "X-ray self-emission imaging used to diagnose 3-D nonuniformities in direct-drive ICF implosions." Rev. Sci. Instrum., v. 87, 11E340 (2016) | 2016 | X-ray self-emission imaging used to diagnose 3-D nonuniformities in direct-drive ICF implosions | [Davis, A. K.; Michel, D. T.; Craxton, R. S.; Epstein, R.; Hohenberger, M.; Mo, T.; Froula, D. H.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [Davis, A. K.; Froula, D. H.] Univ Rochester, Dept Phys, Rochester, NY 14611 USA | direct_drive; icf | | Rev. Sci. Instrum. |
Benstead, J., et al., "A new streaked soft x-ray imager for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 055110 (2016) | 2016 | A new streaked soft x-ray imager for the National Ignition Facility | [Benstead, J.; Morton, J.; Guymer, T. M.; Garbett, W. J.; Rubery, M. S.; Skidmore, J. W.] AWE, Reading RG7 4PR, Berks, England; [Moore, A. S.; Ahmed, M. F.; Soufli, R.; Pardini, T.; Hibbard, R. L.; Bailey, C. G.; Bell, P. M.; Hau-Riege, S.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Bedzyk, M.; Shoup, M. J., III; Reagan, S.; Agliata, T.; Jungquist, R.] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA; [Schmidt, D. W.; Kot, L. B.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Gullikson, E.; Salmassi, F.] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA | half_hohlraum | | Rev. Sci. Instrum. |
Chen, H., et al., "A high-speed two-frame, 1-2 ns gated X-ray CMOS imager used as a hohlraum diagnostic on the National Ignition Facility (invited)." Rev. Sci. Instrum., v. 87, 11E203 (2016) | 2016 | A high-speed two-frame, 1-2 ns gated X-ray CMOS imager used as a hohlraum diagnostic on the National Ignition Facility (invited) | [Chen, Hui; Palmer, N.; Dayton, M.; Carpenter, A.; Schneider, M. B.; Bell, P. M.; Bradley, D. K.; Jones, O. S.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Claus, L. D.; Fang, L.; Kimmel, M. W.; Robertson, G.; Rochau, G.; Sanchez, M. O.; Stahoviak, J. W.; Trotter, D. C.; Porter, J. L.] Sandia Natl Labs, Albuquerque, NM 87123 USA; [Hilsabeck, T.; Kilkenny, J. D.] Gen Atom, San Diego, CA 92186 USA; [Hohenberger, M.] Laser Energet Lab, Rochester, NY 14623 USA | hohlraum; icf | | Rev. Sci. Instrum. |
May, MJ., et al., "Understanding reconstructed Dante spectra using high resolution spectroscopy." Rev. Sci. Instrum., v. 87, 11E330 (2016) | 2016 | Understanding reconstructed Dante spectra using high resolution spectroscopy | [May, M. J.; Widmann, K.; Kemp, G. E.; Thorn, D.; Colvin, J. D.; Schneider, M. B.; Moore, A.; Blue, B. E.] L 170 Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94551 USA; [Weaver, J.] Naval Res Lab, 4555 Overlook Ave SW, Washington, DC 20375 USA | hohlraum; spectroscopy | | Rev. Sci. Instrum. |
Bachmann, B., et al., "Resolving hot spot microstructure using x-ray penumbral imaging (invited)." Rev. Sci. Instrum., v. 87, 11E201 (2016) | 2016 | Resolving hot spot microstructure using x-ray penumbral imaging (invited) | [Bachmann, B.; Field, J.; Masters, N.; Pardini, T.; Rygg, J. R.; Benedetti, L. R.; Doppner, T.; Izumi, N.; LePape, S.; Ma, T.; MacPhee, A. G.; Nagel, S.; Patel, P.; Spears, B.; Landen, O. L.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Hilsabeck, T.; Reed, C.; Alexander, N.; Forsman, A.] Gen Atom, San Diego, CA 92186 USA | icf | | Rev. Sci. Instrum. |
Benedetti, LR., et al., "A comparison of "flat fielding" techniques for x-ray framing cameras." Rev. Sci. Instrum., v. 87, 11D622 (2016) | 2016 | A comparison of "flat fielding" techniques for x-ray framing cameras | [Benedetti, L. R.; Holder, J. P.; Piston, K.; Hargrove, D.; Bradley, D. K.; Bell, P.; Pickworth, L. A.; Khan, S. F.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA; [Trosseille, C.; Raimbourg, J.; Prat, M.] CEA DAM, F-91297 Bruyeres Le Chatel, Arpajon, France | icf | | Rev. Sci. Instrum. |
Khan, SF., et al., "Automated analysis of hot spot X-ray images at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E334 (2016) | 2016 | Automated analysis of hot spot X-ray images at the National Ignition Facility | [Khan, S. F.; Izumi, N.; Glenn, S.; Tommasini, R.; Benedetti, L. R.; Ma, T.; Pak, A.; Springer, P.; Bradley, D. K.; Town, R. P. J.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Kyrala, G. A.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA | icf | | Rev. Sci. Instrum. |
Danly, CR., et al., "Combined neutron and x-ray imaging at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D703 (2016) | 2016 | Combined neutron and x-ray imaging at the National Ignition Facility | [Danly, C. R.; Fatherley, V. E.; Merrill, F. E.; Schmidt, D. W.; Simpson, R. A.; Volegov, P. L.; Wilde, C. H.] Los Alamos Natl Lab, Los Alamos, NM 87544 USA; [Christensen, K.; Fittinghoff, D. N.; Grim, G. P.; Hibbard, R.; Izumi, N.; Jedlovec, D.; Skulina, K.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | icf | | Rev. Sci. Instrum. |
Nagel, SR., et al., "Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate." Rev. Sci. Instrum., v. 87, 11E311 (2016) | 2016 | Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate | [Nagel, S. R.; Benedetti, L. R.; Bradley, D. K.; Izumi, N.; Khan, S.; Ma, T.; Pak, A.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA; [Hilsabeck, T. J.] Gen Atom Co, POB 85608, San Diego, CA 92186 USA; [Kyrala, G. A.] Los Alamos Natl Lab, POB 1663, Los Alamos, NM 87507 USA | icf | | Rev. Sci. Instrum. |
Hartouni, EP., et al., "Uncertainty analysis of signal deconvolution using a measured instrument response function." Rev. Sci. Instrum., v. 87, 11D841 (2016) | 2016 | Uncertainty analysis of signal deconvolution using a measured instrument response function | [Hartouni, E. P.; Beeman, B.; Caggiano, J. A.; Cerjan, C.; Eckart, M. J.; Grim, G. P.; Hatarik, R.; Moore, A. S.; Munro, D. H.; Phillips, T.; Sayre, D. B.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | icf | | Rev. Sci. Instrum. |
Kabadi, NV., et al., "Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D817 (2016) | 2016 | Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility | [Kabadi, N. V.; Sio, H.; Johnson, M. Gatu; Frenje, J. A.; Li, C. K.; Seguin, F.; Petrasso, R.] MIT, Plasma Sci & Fus Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Glebov, V.; Forrest, C.; Knauer, J.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [MacPhee, A.; Rinderknecht, H. G.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | icf | | Rev. Sci. Instrum. |
Lanier, NE., et al., "Using VISAR to assess the M-band isotropy in hohlraums." Rev. Sci. Instrum., v. 87, 11D621 (2016) | 2016 | Using VISAR to assess the M-band isotropy in hohlraums | [Lanier, N. E.; Kline, J. L.] Los Alamos Natl Lab, Los Alamos, NM 87544 USA; [Morton, J.] AWE Plc, Reading RG7 4PR, Berks, England | indirect_drive; hohlraum | | Rev. Sci. Instrum. |
Johnson, MG., et al., "High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D816 (2016) | 2016 | High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility | [Johnson, M. Gatu; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Seguin, F. H.] MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Bionta, R. M.; Casey, D. T.; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R.; Sayre, D. B.; Skulina, K.; Yeamans, C. B.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Farrell, M. P.; Hoppe, M.; Kilkenny, J. D.; Reynolds, H. G.; Schoff, M. E.] Gen Atom, San Diego, CA 92186 USA | indirect_drive; icf | | Rev. Sci. Instrum. |
Doppner, T., et al., "eHXI: a permanently installed, hard x-ray imager for the National Ignition Facility." J. Instrum., v. 11, P06010 (2016) | 2016 | eHXI: a permanently installed, hard x-ray imager for the National Ignition Facility | [Doppner, T.; Bachmann, B.; Albert, F.; Bell, P.; Burns, S.; Celeste, J.; Chow, R.; Divol, L.; Dewald, E. L.; Huntington, C. M.; Izumi, N.; LaCaille, G.; Landen, O. L.; Palmer, N.; Park, H. -S.; Thomas, C. A.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA; [Hohenberger, M.] Univ Rochester, Laser Energet Lab, 250 East River Rd, Rochester, NY 14623 USA; [LaCaille, G.] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, 2108 Allston Way, Berkeley, CA 94720 USA | indirect_drive; icf | | J. Instrum. |
Reynolds, HG., et al., "Improvements in Fabrication of Elastic Scattering Foils Used to Measure Neutron Yield by the Magnetic Recoil Spectrometer." Fusion Sci. Technol., v. 70, p.365-371 (2016) | 2016 | Improvements in Fabrication of Elastic Scattering Foils Used to Measure Neutron Yield by the Magnetic Recoil Spectrometer | [Reynolds, H. G.; Schoff, M. E.; Farrell, M. P.] Gen Atom, POB 85608, San Diego, CA 92186 USA; [Johnson, M. Gatu; Frenje, J. A.] MIT, Plasma Sci & Fus Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Bionta, R. M.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | indirect_drive; nuclear_science | | Fusion Sci. Technol. |
Ratkiewicz, A., et al., "A recoverable gas-cell diagnostic for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D825 (2016) | 2016 | A recoverable gas-cell diagnostic for the National Ignition Facility | [Ratkiewicz, A.; Hopkins, L. Berzak; Bleuel, D. L.; Cassata, W. S.; Velsko, C. A.; Yeamans, C. B.] Lawrence Livermore Natl Lab, Livermore, CA 95440 USA; [Bernstein, L. A.; van Bibber, K.; Goldblum, B. L.] Univ Calif Berkeley, Berkeley, CA 94720 USA; [Siem, S.] Univ Oslo, N-0316 Oslo, Norway; [Wiedeking, M.] iThemba LABS, ZA-7129 Somerset West, South Africa | nuclear_science | nuclear physics | Rev. Sci. Instrum. |
Gharibyan, N., et al., "Recent advances and results from the solid radiochemistry nuclear diagnostic at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D813 (2016) | 2016 | Recent advances and results from the solid radiochemistry nuclear diagnostic at the National Ignition Facility | [Gharibyan, N.; Shaughnessy, D. A.; Moody, K. J.; Grant, P. M.; Despotopulos, J. D.; Faye, S. A.; Jedlovec, D. R.; Yeamans, C. B.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA | nuclear_science | | Rev. Sci. Instrum. |
Yeamans, CB., et al., "A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D702 (2016) | 2016 | A neutron activation spectrometer and neutronic experimental platform for the National Ignition Facility | [Yeamans, C. B.; Gharibyan, N.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | nuclear_science | | Rev. Sci. Instrum. |
Edwards, ER., et al., "Determination of relative krypton fission product yields from 14 MeV neutron induced fission of U-238 at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D838 (2016) | 2016 | Determination of relative krypton fission product yields from 14 MeV neutron induced fission of U-238 at the National Ignition Facility | [Edwards, E. R.] Univ Calif Berkeley, Dept Nucl Engn, Berkeley, CA 94720 USA; [Cassata, W. S.; Velsko, C. A.; Yeamans, C. B.; Shaughnessy, D. A.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA | nuclear_science | | Rev. Sci. Instrum. |
Zylstra, AB., et al., "Proton pinhole imaging on the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E704 (2016) | 2016 | Proton pinhole imaging on the National Ignition Facility | [Zylstra, A. B.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Park, H. -S.; Ross, J. S.; Higginson, D. P.; Huntington, C.; Pollock, B.; Remington, B.; Rinderknecht, H. G.; Ryutov, D.; Turnbull, D.; Wilks, S. C.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Fiuza, F.] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA; [Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Seguin, F. H.] MIT, Plasma Sci & Fus Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA | proton_radiography; astrophysics | plasma physics | Rev. Sci. Instrum. |
Sutcliffe, GD., et al., "A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D812 (2016) | 2016 | A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility | [Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Johnson, M. Gatu; Seguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.] MIT, Plasma Sci & Fus Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Park, H. -S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Zylstra, A. B.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Rosenberg, M. J.; Glebov, V. Yu.] Laser Energet Lab, Rochester, NY 14623 USA | proton_radiography; astrophysics | plasma physics | Rev. Sci. Instrum. |
Pickworth, LA., et al., "The National Ignition Facility modular Kirkpatrick-Baez microscope." Rev. Sci. Instrum., v. 87, 11E316 (2016) | 2016 | The National Ignition Facility modular Kirkpatrick-Baez microscope | [Pickworth, L. A.; Ayers, J.; Bell, P.; Brejnholt, N. F.; Buscho, J. G.; Bradley, D.; Decker, T.; Hau-Riege, S.; McCarville, T.; Pardini, T.; Vogel, J.; Walton, C.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Kilkenny, J.] Gen Atom, San Diego, CA 92121 USA | radiography | | Rev. Sci. Instrum. |
Izumi, N., et al., "Observation of hohlraum-wall motion with spectrally selective x-ray imaging at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E321 (2016) | 2016 | Observation of hohlraum-wall motion with spectrally selective x-ray imaging at the National Ignition Facility | [Izumi, N.; Meezan, N. B.; Divol, L.; Hall, G. N.; Barrios, M. A.; Jones, O.; Landen, O. L.; Kroll, J. J.; Vonhof, S. A.; Nikroo, A.; Bailey, C. G.; Hardy, C. M.; Ehrlich, R. B.; Town, R. P. J.; Bradley, D. K.; Hinkel, D. E.; Moody, J. D.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Jaquez, J.] Gen Atom, San Diego, CA USA | spectroscopy | | Rev. Sci. Instrum. |
Benedetti, LR., et al., "Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging." Rev. Sci. Instrum., v. 87, 023511 (2016) | 2016 | Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging | [Benedetti, L. R.; Holder, J. P.; Perkins, M.; Brown, C. G.; Anderson, C. S.; Allen, F. V.; Petre, R. B.; Hargrove, D.; Glenn, S. M.; Simanovskaia, N.; Bradley, D. K.; Bell, P.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Perkins, M.] Varian, Las Vegas, NV 89119 USA; [Simanovskaia, N.] Pacific Biosci, Menlo Pk, CA 94025 USA | spectroscopy | | Rev. Sci. Instrum. |
Moore, AS., et al., "Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager." Rev. Sci. Instrum., v. 87, 11E313 (2016) | 2016 | Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager | [Moore, A. S.; Ahmed, M. F.; Soufli, R.; Pardini, T.; Hibbard, R. L.; Bailey, C. G.; Bell, P. M.; Hau-Riege, S.] Lawrence Livermore Natl Lab, POB 808, Livermore, CA 94551 USA; [Benstead, J.; Morton, J.; Guymer, T. M.; Garbett, W. J.; Rubery, M. S.; Skidmore, J. W.] AWE Aldermaston, Directorate Sci & Technol, Reading RG7 4PR, Berks, England; [Bedzyk, M.; Shoup, M. J., III; Regan, S. P.; Agliata, T.; Jungquist, R.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [Schmidt, D. W.; Kot, L. B.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Gullikson, E.; Salmassi, F.] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA | spectroscopy | | Rev. Sci. Instrum. |
Ma, T., et al., "Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF." Rev. Sci. Instrum., v. 87, 11E327 (2016) | 2016 | Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF | [Ma, T.; Chen, H.; Patel, P. K.; Schneider, M. B.; Barrios, M. A.; Casey, D. T.; Hammel, B. A.; Hopkins, L. F. Berzak; Jarrott, L. C.; Khan, S. F.; Nora, R.; Pak, A.; Scott, H. A.; Spears, B. K.; Weber, C. R.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Chung, H. -K.] IAEA, Vienna, Austria; [Lahmann, B.; Sio, H.] MIT, Plasma Fus & Sci Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Rosenberg, M. J.; Regan, S. P.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA | spectroscopy; icf | | Rev. Sci. Instrum. |
Doppner, T., et al., "Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E515 (2016) | 2016 | Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility | [Doppner, T.; Bachmann, B.; Emig, J.; Hardy, M.; Kalantar, D. H.; Kritcher, A. L.; Landen, O. L.; Ma, T.; Wood, R. D.] Lawrence Livermore Natl Lab, Livermore, CA 94720 USA; [Kraus, D.; Falcone, R. W.; Saunders, A. M.] Univ Calif Berkeley, Berkeley, CA 94720 USA; [Neumayer, P.] Gesell Schwerionenphys, Darmstadt, Germany; [Falcone, R. W.] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA; [Fletcher, L. B.] SLAC Natl Accelerator Lab, Menlo Pk, CA 94720 USA | xrts | eos/material science | Rev. Sci. Instrum. |
Hall, GN., et al., "Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography." Rev. Sci. Instrum., v. 87, 11E310 (2016) | 2016 | Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography | [Hall, G. N.; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA; [Lee, J. J.; Romano, E.] Natl Secur Technol LLC, 161 S Vasco Rd, Livermore, CA 94551 USA | | | Rev. Sci. Instrum. |
Haugh, MJ., et al., "Measuring the diffraction properties of an imaging quartz(211) crystal." Rev. Sci. Instrum., v. 87, 063103 (2016) | 2016 | Measuring the diffraction properties of an imaging quartz(211) crystal | [Haugh, M. J.; Jacoby, K. D.; Koch, J. A.] Natl Secur Technol LLC, Livermore, CA 94550 USA; [Chen, H.; Schneider, M. B.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA; [Hill, K. W.] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA | | | Rev. Sci. Instrum. |
Wink, CW., et al., "Signal and background considerations for the MRSt on the National Ignition Facility (NIF)." Rev. Sci. Instrum., v. 87, 11D808 (2016) | 2016 | Signal and background considerations for the MRSt on the National Ignition Facility (NIF) | [Wink, C. W.; Frenje, J. A.; Johnson, M. Gatu; Li, C. K.; Seguin, F. H.; Petrasso, R. D.] MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Hilsabeck, T. J.; Kilkenny, J. D.] Gen Atom, San Diego, CA 92186 USA; [Bionta, R.; Khater, H. Y.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Casey, DT., et al., "Fluence-compensated down-scattered neutron imaging using the neutron imaging system at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E715 (2016) | 2016 | Fluence-compensated down-scattered neutron imaging using the neutron imaging system at the National Ignition Facility | [Casey, D. T.; Munro, D. H.; Grim, G. P.; Landen, O. L.; Spears, B. K.; Fittinghoff, D. N.; Field, J. E.; Smalyuk, V. A.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Volegov, P. L.; Merrill, F. E.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA | | | Rev. Sci. Instrum. |
Swadling, GF., et al., "Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic." Rev. Sci. Instrum., v. 87, 11D603 (2016) | 2016 | Design calculations for a xenon plasma x-ray shield to protect the NIF optical Thomson scattering diagnostic | [Swadling, G. F.; Ross, J. S.; Datte, P.; Moody, J.; Divol, L.; Jones, O.; Landen, O.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Hill, KW., et al., "Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF)." Rev. Sci. Instrum., v. 87, 11E344 (2016) | 2016 | Development of a high resolution x-ray spectrometer for the National Ignition Facility (NIF) | [Hill, K. W.; Bitter, M.; Delgado-Aparicio, L.; Efthimion, P. C.; Ellis, R.; Gao, L.; Maddox, J.; Pablant, N. A.] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA; [Schneider, M. B.; Chen, H.; Ayers, S.; Kauffman, R. L.; MacPhee, A. G.; Beiersdorfer, P.; Bettencourt, R.; Ma, T.; Nora, R. C.; Scott, H. A.; Thorn, D. B.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Kilkenny, J. D.] Gen Atom Co, San Diego, CA 92121 USA; [Nelson, D.; Shoup, M., III] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [Maron, Y.] Weizmann Inst Sci, IL-76100 Rehovot, Israel | | | Rev. Sci. Instrum. |
Jarrott, LC., et al., "Hotspot electron temperature from x-ray continuum measurements on the NIF." Rev. Sci. Instrum., v. 87, 11E534 (2016) | 2016 | Hotspot electron temperature from x-ray continuum measurements on the NIF | [Jarrott, L. C.; Benedetti, L. R.; Chen, H.; Izumi, N.; Khan, S. F.; Ma, T.; Nagel, S. R.; Landen, O. L.; Pak, A.; Patel, P. K.; Schneider, M.; Scott, H. A.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Ross, JS., et al., "Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E510 (2016) | 2016 | Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility | [Ross, J. S.; Datte, P.; Divol, L.; Galbraith, J.; Hatch, B.; Landen, O.; Manuel, A. M.; Molander, W.; Moody, J. D.; Swadling, G.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Froula, D. H.; Katz, J.] Univ Rochester, Lab Laser Energet, Rochester, NY 14623 USA; [Glenzer, S. H.] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA; [Kilkenny, J.] Gen Atom, San Diego, CA 92186 USA; [Montgomery, D. S.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Weaver, J.] Naval Res Lab, Plasma Phys Div, Washington, DC 20375 USA | | | Rev. Sci. Instrum. |
Datte, PS., et al., "The design of the optical Thomson scattering diagnostic for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E549 (2016) | 2016 | The design of the optical Thomson scattering diagnostic for the National Ignition Facility | [Datte, P. S.; Ross, J. S.; Daub, K. D.; Galbraith, J.; Hatch, B.; Kilkenny, J.; Landen, O.; Manha, D.; Manuel, A. M.; Molander, W.; Moody, J.; Swadling, G. F.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Froula, D. H.; Katz, J.] Univ Rochester, Lab Laser Energet, Rochester, NY 14623 USA; [Glenzer, S.] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA; [Montgomery, D.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Weaver, J.] Naval Res Lab, Plasma Phys Div, Washington, DC 20375 USA | | | Rev. Sci. Instrum. |
Fatherley, VE., et al., "Design of the polar neutron-imaging aperture for use at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D821 (2016) | 2016 | Design of the polar neutron-imaging aperture for use at the National Ignition Facility | [Fatherley, V. E.; Martinez, J. I.; Merrill, F. E.; Oertel, J. A.; Schmidt, D. W.; Volegov, P. L.; Wilde, C. H.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Barker, D. A.; Fittinghoff, D. N.; Hibbard, R. L.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA | | | Rev. Sci. Instrum. |
Fournier, KB., et al., "X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D421 (2016) | 2016 | X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility | [Fournier, K. B.; Brown, C. G., Jr.; Yeoman, M. F.; Compton, S.; Holdener, F. R.; Kemp, G. E.; Blue, B. E.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94551 USA; [Fisher, J. H.; Newlander, C. D.; Gilliam, R. P.; Froula, N.] Fifth Gait Technol Inc, 14040 Camden Circle, Huntsville, AL 35803 USA; [Seiler, S. W.; Davis, J. F.; Lerch, Maj. A.] Def Threat Reduct Agcy, 8725 John J Kingman Rd, Ft Belvoir, VA 22060 USA; [Hinshelwood, D.] Naval Res Lab, 4555 Overlook Ave SW, Washington, DC 20375 USA; [Lilly, M.] Dynasen Inc, 20 Arnold Pl, Goleta, CA 93117 USA | | | Rev. Sci. Instrum. |
Kilkenny, JD., et al., "The National Ignition Facility Diagnostic Set at the Completion of the National Ignition Campaign, September 2012." Fusion Sci. Technol., v. 69, p.420-451 (2016) | 2016 | The National Ignition Facility Diagnostic Set at the Completion of the National Ignition Campaign, September 2012 | [Kilkenny, J. D.] Gen Atom, La Jolla, CA 92121 USA; [Bell, P. M.; Bradley, D. K.; Bleuel, D. L.; Caggiano, J. A.; Dewald, E. L.; Hsing, W. W.; Kalantar, D. H.; Kauffman, R. L.; Larson, D. J.; Moody, J. D.; Schneider, D. H.; Schneider, M. B.; Shaughnessy, D. A.; Shelton, R. T.; Stoeffl, W.; Widmann, K.; Yeamans, C. B.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Batha, S. H.; Grim, G. P.; Herrmann, H. W.; Merrill, F. E.; Leeper, R. J.; Oertel, J. A.] Los Alamos Natl Lab, POB 1663, Los Alamos, NM 87545 USA; [Sangster, T. C.; Edgell, D. H.; Hohenberger, M.; Glebov, V. Yu.; Regan, S. P.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [Kilkenny, J. D.; Frenje, J. A.; Gatu-Johnson, M.; Petrasso, R. D.; Rinderknecht, H. G.; Zylstra, A. B.] MIT, Cambridge, MA 02139 USA; [Cooper, G. W.; Ruiz, C.] Sandia Natl Labs, Albuquerque, NM 87123 USA | | | Fusion Sci. Technol. |
Herrmann, HW., et al., "Next generation gamma-ray Cherenkov detectors for the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11E732 (2016) | 2016 | Next generation gamma-ray Cherenkov detectors for the National Ignition Facility | [Herrmann, H. W.; Kim, Y. H.; McEvoy, A. M.; Zylstra, A. B.; Young, C. S.; Lopez, F. E.; Griego, J. R.; Fatherley, V. E.; Oertel, J. A.; Batha, S. H.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA; [Stoeffl, W.; Khater, H.; Hernandez, J. E.; Carpenter, A.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Rubery, M. S.; Horsfield, C. J.; Gales, S.; Leatherland, A.] Atom Weap Estab, Aldermaston RG7 4PR, Berks, England; [Hilsabeck, T.; Kilkenny, J. D.] Gen Atom, San Diego, CA 92186 USA; [Malone, R. M.] Natl Secur Technol LLC, Los Alamos, NM 87544 USA; [Hares, J. D.] Kentech Instruments LTD, Wallingford, Oxon, England; [Milnes, J.] Photeck LTD, St Leonards On Sea, England; [Shmayda, W. T.; Stoeckl, C.] Laser Energet Lab, Rochester, NY 14623 USA | | | Rev. Sci. Instrum. |
Jaquez, J., et al., "Fabrication, Characterization, and Modeling of Comixed Films for NXS Calibration Targets." Fusion Sci. Technol., v. 70, p.358-364 (2016) | 2016 | Fabrication, Characterization, and Modeling of Comixed Films for NXS Calibration Targets | [Jaquez, Javier; Farrell, Mike; Huang, Haibo; Nikroo, Abbas] Gen Atom, San Diego, CA 92121 USA; [Regan, Sean] Lab Laser Energet, Rochester, NY 14623 USA; [Fournier, Kevin; Garcia, Maria Alejandra Barrios; Perez, Frederic] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA | | | Fusion Sci. Technol. |
MacPhee, AG., et al., "Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)." Rev. Sci. Instrum., v. 87, 11E202 (2016) | 2016 | Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited) | [MacPhee, A. G.; Hassett, J.; Hatch, B. W.; Bell, P. M.; Bradley, D. K.; Datte, P. S.; Landen, O. L.; Palmer, N. E.; Piston, K. W.; Rekow, V. V.] Lawrence Livermore Natl Lab, POB 808, Livermore, CA 94551 USA; [Dymoke-Bradshaw, A. K. L.; Hares, J. D.] Kentech Instruments Ltd, Isis Bldg,Howbery Pk, Wallingford OX10 8BD, Oxon, England; [Hassett, J.] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA; [Meadowcroft, A. L.] AWE Aldermaston, Reading RG7 4PR, Berks, England; [Hilsabeck, T. J.; Kilkenny, J. D.] Gen Atom, POB 85608, San Diego, CA 92186 USA | | | Rev. Sci. Instrum. |
Frenje, JA., et al., "The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)." Rev. Sci. Instrum., v. 87, 11D806 (2016) | 2016 | The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF) | [Frenje, J. A.; Wink, C. W.; Johnson, M. Gatu; Li, C. K.; Seguin, F. H.; Petrasso, R. D.] MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Hilsabeck, T. J.; Kilkenny, J. D.] Gen Atom, San Diego, CA 92186 USA; [Bell, P.; Bionta, R.; Cerjan, C.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Ross, PW., et al., "Design of the opacity spectrometer for opacity measurements at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D623 (2016) | 2016 | Design of the opacity spectrometer for opacity measurements at the National Ignition Facility | [Ross, P. W.; Huffman, E. J.; King, J. A.; Opachich, Y. P.] Natl Secur Technol LLC, 161 S Vasco Rd, Livermore, CA 94550 USA; [Heeter, R. F.; Ahmed, M. F.; Liedahl, D. A.; Schneider, M. B.] Lawrence Livermore Natl Lab, POB 808, Livermore, CA 94550 USA; [Dodd, E.; Perry, T. S.] Los Alamos Natl Lab, POB 1663, Los Alamos, NM 87545 USA | | | Rev. Sci. Instrum. |
Haugh, MJ., et al., "A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal." Rev. Sci. Instrum., v. 87, 11D612 (2016) | 2016 | A technique for measuring the quality of an elliptically bent pentaerythritol [PET(002)] crystal | [Haugh, M. J.; Jacoby, K. D.] Natl Secur Technol LLC, Livermore, CA 94550 USA; [Barrios, M. A.; Thorn, D.; Emig, J. A.; Schneider, M. B.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Sayre, DB., et al., "Calibration of scintillation-light filters for neutron time-of-flight spectrometers at the National Ignition Facility." Rev. Sci. Instrum., v. 87, 11D802 (2016) | 2016 | Calibration of scintillation-light filters for neutron time-of-flight spectrometers at the National Ignition Facility | [Sayre, D. B.; Barbosa, F.; Caggiano, J. A.; Eckart, M. J.; Grim, G. P.; Hartouni, E. P.; Hatarik, R.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [DiPuccio, V. N.; Weber, F. A.] Natl Secur Technol, Livermore, CA 94551 USA | | | Rev. Sci. Instrum. |
Datte, PS., et al., "Impulse responses of visible phototubes used in National Ignition Facility neutron time of flight diagnostics." Rev. Sci. Instrum., v. 87, 11D837 (2016) | 2016 | Impulse responses of visible phototubes used in National Ignition Facility neutron time of flight diagnostics | [Datte, P. S.; Eckart, M.; Moore, A. S.; Thompson, W.; de Dios, G. Vergel] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Opachich, YP., et al., "Structured photocathodes for improved high-energy x-ray efficiency in streak cameras." Rev. Sci. Instrum., v. 87, 11E331 (2016) | 2016 | Structured photocathodes for improved high-energy x-ray efficiency in streak cameras | [Opachich, Y. P.; Huffman, E.; Koch, J. A.] Natl Secur Technol LLC, Livermore, CA 94551 USA; [Bell, P. M.; Bradley, D. K.; Hatch, B.; Landen, O. L.; MacPhee, A. G.; Nagel, S. R.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Chen, N.; Gopal, A.; Udin, S.] Nanoshift LLC, Emeryville, CA 94608 USA; [Feng, J.] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA; [Hilsabeck, T. J.] Gen Atom, San Diego, CA 92121 USA | | | Rev. Sci. Instrum. |
Holder, JP., et al., "Characterization of x-ray framing cameras for the National Ignition Facility using single photon pulse height analysis." Rev. Sci. Instrum., v. 87, 11D618 (2016) | 2016 | Characterization of x-ray framing cameras for the National Ignition Facility using single photon pulse height analysis | [Holder, J. P.; Benedetti, L. R.; Bradley, D. K.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |
Park, J., et al., "The implementation and data analysis of an interferometer for intense short pulse laser experiments." High Power Laser Sci., v. 4, e26 (2016) | 2016 | The implementation and data analysis of an interferometer for intense short pulse laser experiments | Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; Univ Calif, Davis, CA 95616 USA; [Park, Jaebum; Chen, Hui] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Park, Jaebum; Baldis, Hector A.] Univ Calif Davis, Davis, CA 95616 USA | | | High Power Laser Sci. |
Rasmus, AM., et al., "Detailed characterization of the LLNL imaging proton spectrometer." Rev. Sci. Instrum., v. 87, 11D831 (2016) | 2016 | Detailed characterization of the LLNL imaging proton spectrometer | [Rasmus, A. M.] Los Alamos Natl Lab, Los Alamos, NM 87544 USA; [Rasmus, A. M.; Manuel, M. J. -E.; Kuranz, C. C.; Klein, S. R.; Belancourt, P. X.; Fein, J. R.; MacDonald, M. J.; Drake, R. P.] Univ Michigan, Ann Arbor, MI 48109 USA; [Hazi, A. U.; Pollock, B. B.; Park, J.; Williams, G. J.; Chen, H.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [MacDonald, M. J.] SLAC Natl Accelerator Lab, Menlo Pk, CA 94025 USA | | | Rev. Sci. Instrum. |
Saunders, AM., et al., "X-ray Thomson scattering measurements from hohlraum-driven spheres on the OMEGA laser." Rev. Sci. Instrum., v. 87, 11E724 (2016) | 2016 | X-ray Thomson scattering measurements from hohlraum-driven spheres on the OMEGA laser | [Saunders, A. M.; Falcone, R. W.] Univ Calif Berkeley, Berkeley, CA 94720 USA; [Jenei, A.; Doppner, T.; Kritcher, A.; Landen, O. L.; Nilsen, J.; Swift, D.] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA; [Kraus, D.] Helmholtz Zentrum Dresden Rossendorf, Bautzner Landstr 400, D-01328 Dresden, Germany | | | Rev. Sci. Instrum. |
Beiersdorfer, P., et al., "Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer." Rev. Sci. Instrum., v. 87, 063501 (2016) | 2016 | Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer | [Beiersdorfer, P.; Magee, E. W.; Brown, G. V.; Chen, H.; Emig, J.; Hell, N.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Hell, N.] Univ Erlangen Nurnberg, Dr Remeis Sternwarte, D-96049 Bamberg, Germany; [Hell, N.] Univ Erlangen Nurnberg, ECAP, D-96049 Bamberg, Germany; [Bitter, M.; Hill, K. W.] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA; [Allan, P.; Brown, C. R. D.; Hill, M. P.; Hoarty, D. J.; Hobbs, L. M. R.; James, S. F.] AWE Plc, Directorate Res & Appl Sci, Reading RG7 4PR, Berks, England | | | Rev. Sci. Instrum. |
Pardini, T., et al., "Aperiodic Mo/Si multilayers for hard X-rays." Opt. Express, v. 24, p.18642-18648 (2016) | 2016 | Aperiodic Mo/Si multilayers for hard X-rays | [Pardini, Tom; Alameda, Jennifer; Robinson, Jeff; Soufli, Regina; Spiller, Eberhard; Walton, Chris; Hau-Riege, Stefan P.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Platonov, Yuriy] Rigaku Innovat Technol Inc, Auburn Hills, MI 48326 USA | | | Opt. Express |
Maddox, BR., et al., "Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction." Rev. Sci. Instrum., v. 87, 083901 (2016) | 2016 | Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction | [Maddox, B. R.; Akin, M. C.; Teruya, A.; Hunt, D.; Hahn, D.; Cradick, J.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Morgan, D. V.] Natl Secur Technol LLC, Los Alamos, NM 87544 USA | | | Rev. Sci. Instrum. |
Sio, H., et al., "A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA." Rev. Sci. Instrum., v. 87, 11D701 (2016) | 2016 | A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA | [Sio, H.; Frenje, J. A.; Johnson, M. Gatu; Sutcliffe, G.; Petrasso, R. D.] MIT, Plasma Sci & Fus Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA; [Katz, J.; Stoeckl, C.; Weiner, D.; Bedzyk, M.; Glebov, V.; Sorce, C.; Sangster, T. C.; Regan, S. P.] Univ Rochester, Laser Energet Lab, 250 E River Rd, Rochester, NY 14623 USA; [Rinderknecht, H. G.] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA; [Zylstra, A. B.; Kwan, T.; Le, A.; Simakov, A. N.; Taitano, W. T.; Chacon, L.; Keenan, B.; Shah, R.] Los Alamos Natl Lab, Los Alamos, NM 87545 USA | | | Rev. Sci. Instrum. |
Erskine, DJ., et al., "Ghost fringe removal techniques using Lissajous data presentation." Rev. Sci. Instrum., v. 87, 033106 (2016) | 2016 | Ghost fringe removal techniques using Lissajous data presentation | [Erskine, David J.; Eggert, J. H.; Celliers, P. M.] Lawrence Livermore Natl Lab, L-487, Livermore, CA 94551 USA; [Hicks, D. G.] Swinburne Univ Technol, Ctr Microphoton, Hawthorn, Vic 3122, Australia | | | Rev. Sci. Instrum. |
Gregor, MC., et al., "Absolute calibration of the OMEGA streaked optical pyrometer for temperature measurements of compressed materials." Rev. Sci. Instrum., v. 87, 114903 (2016) | 2016 | Absolute calibration of the OMEGA streaked optical pyrometer for temperature measurements of compressed materials | [Gregor, M. C.; Boni, R.; Sorce, A.; Kendrick, J.; Mccoy, C. A.; Polsin, D. N.; Boehly, T. R.] Univ Rochester, Lab Laser Energet, 250 East River Rd, Rochester, NY 14623 USA; [Gregor, M. C.; Polsin, D. N.] Univ Rochester, Dept Phys & Astron, Rochester, NY 14620 USA; [Mccoy, C. A.] Univ Rochester, Dept Mech Engn, Rochester, NY 14620 USA; [Celliers, P. M.; Collins, G. W.; Fratanduono, D. E.; Eggert, J. H.; Millot, M.] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA | | | Rev. Sci. Instrum. |